This
is
a
+
10
Vdc
only
input,
three-axis
sensor
array
comprised
of
three
ARS-04
sensors
in
a
mounting
block
plus
a
voltage
conditioner,
an
amplifier
and
signal
conditioning
board
mounted
and
hermetically
sealed
in
an
aluminum
cube.
The
Dynacube™-S
has
three
surfaces
which
can
be
used
for
mounting
three
linear
accelerometers
to
make
a
6
degree-of-freedom
sensor
array.
Linear
accelerometers
may
be
supplied
by
ATA
Sensors
or
customer
supplied.
Scale
Factor
(Sensitivity)
--
The
standard
scale
factor
for
the
sensors
used
in
the
Dynacube™
–S
is
35
mV/(rad/sec).
We
can
provide
custom
scale
factors
to
order
over
a
range
of
values.
Any
other
desired
scale
factor
must
be
specified
in
mV/(rad/sec)
or
mV/(deg/sec).
However,
increasing
scale
factors
beyond
this
standard
value
will
result
in
a
reduction
in
frequency
range.
All
three
sensors
in
the
Dynacube™-S
will
supplied
to
the
same
scale
factor
unless
otherwise
specified
in
custom
order
form.
Range
--
The
output
signal
range
is
determined
by
dividing
the
maximum
output
voltage
by
the
scale
factor.
A
higher
scale
factor
will
result
in
a
more
limited
range.
A
standard
Dynacube™-S
with
a
35
mV/(rad/sec)
scale
factor
and
an
output
power
voltage
of
±3.5
V
will
have
an
angular
velocity
range
of
±
100
rad/sec
in
each
of
the
three
axis.
Input
Voltages
(Excitation)
--
Standard
input
voltage
of
+
10
Vdc
only
is
used
for
the
Dynacube™-S.
An
internal
voltage
regulator
converts
the
single
voltage
input
to
the
dual
voltage
required
by
the
sensors
in
the
Dynacube-S
.
Signal
Conditioning
and
Power
Supply
Requirements
--
The
Dynacube™-S
may
be
operated
without
a
separate
in-line
signal
conditioning
unit
if
the
standard
customer
power
supply
is
well
regulated
and
without
noise,
and
if
the
sensor
output
cables
are
of
proper
impedance,
not
more
than
15
to
20
feet
in
length,
and
not
subject
to
induced
noise
from
external
EMI
sources.
ATA
Sensors
supplies
optional
cables
for
the
Dynacube™
which
have
the
proper
connectors,
use
Teflon®
insulated
wire
with
twisted
pairs
and
heavy
metal
shielding
to
minimize
noise.
Cables
and
Connectors
--
Two
cable
connection
options
are
offered
for
the
Dynacube™-S
Triaxial.
Cable
CA-04A
is
specified
when
no
ILC
is
used.
Standard
cable
length
is
approximately
7
meters
(23
feet)
and
this
is
supplied
with
the
sensor
mating
AirBorn®
“M”
series
connector
on
one
end
and
un-terminated
pigtail
at
the
other
to
allow
for
the
customer
to
add
their
own
connection
to
measurement
equipment.
Two
screws
are
supplied
with
the
cable
CA-04A
to
lock
the
connector
to
the
sensor.
The
cable
CA-05A
is
specified
when
an
ILC
box
will
be
used.
This
is
a
5.5
meter
cable
which
goes
from
the
sensor
connector
to
the
ILC
box. The ILC box utilizes a
military
specification
AirBorn®
connectors
(male)
M
series.
The
output
side
of
the
ILC
box
uses
corresponding
CA-03A
cable
which
is
1.5
meters
in
length,
has
AirBorn®
6
pin
connectors
at
the
ILC
box
end,
and
pigtails
at
the
other
end
to
allow
customer
interface
connectors
to
be
added.
Custom
machined
connector
housings
allow
the
connectors
to
be
locked
to
the
ILC
using
screws
provided.
In-Line-Converter
(ILC)
--
modules
are
offered
by
ATA
Sensors
to
provide
a
complete
measurement
solution
for
power
regulation
and
signal
conditioning
/
amplification.
The
ILC
modules
applicable
to
the
Dynacube™–S
triaxial
are:
DYNA-ILC
--
This
is
a
three
sensor
ILC
unit
which
provides
signal
conditioning
or
amplification
in
a
small
rugged
in-line
module.
Units
can
only
be
configured
at
the
time
of
manufacture,
since
they
are
fully
encapsulated
with
special
epoxy
resins
for
ruggedness
and
durability
at
assembly.
Signal
conversion
and
gain
options
are
exclusive;
only
one
or
the
other
may
be
specified.
-
The
DYNA-ILC
power
conversion
option
is
not
applicable
for
the
Dynacube™-S
which
requires
only
a
single
voltage
input.
-
As
a
signal
conditioner,
the
ILC
can
covert
the
standard
angular
velocity
output
of
the
sensor
to
an
angular
acceleration
signal.
(The
calibration
data
sheet
provided
with
the
DYNA-ILCxA
will
specify
the
volts-per-volts
output
of
the
acceleration
signal
at
10
Hz.
and
at
100
Hz.
This
is
a
differential
circuit.
The
gain
at
100
Hz.
will
be
ten
times
that
at
10
Hz.)
.
The
order
number
for
an
ILC
for
signal
conversion
from
velocity
to
acceleration
has
the
letter
“A”
as
the
second
ILC
option
indicator.
The
output
signals
of
all
three
sensors
will
be
converted
unless
a
custom
order
configuration
is
specified.1.
-
As
an
amplifier,
the
ILC
will
supply
an
amplified
signal
with
gain
of
1
to
1000
times
normal
signal
output.
Standard
versions
are
available
in
1,
10,
100,
or
1000
times
gain.
The
order
number
for
an
ILC
without
additional
gain
(1x)
is
“F”.
The
order
number
for
an
ILC
for
signal
amplification
from
1
to
10x
has
the
letter
“G”
as
the
second
ILC
option
indicator.
For
gain
from
1
to
100x,
the
letter
“H”
is
specified.
For
gain
of
1000x,
the
letter
“L”
is
specified.
(See
examples
below.)
Note
that
either
gain
or
acceleration
signal
output
can
be
supplied,
not
both.
The
gain
for
all
three
sensor
output
signals
will
be
the
same
unless
a
custom
order
configuration
is
specified.1.
Allowable
ILC
Order
Numbers
for
Dynacube™-S Triaxial:
DYNA-ILC
-NA
DYNA-ILC
-NG
DYNA-ILC
-NH
DYNA-ILC
-NL |
Signal
conversion
from
velocity
to
acceleration
only
Signal
amplification
of
10x
only
Signal
amplification
of
100x
only
Signal
amplification
of
1000x
only
|
1.Custom
order
configurations
require
special
quotations
for
price
and
availability.
Dynacube™
is
a
registered
trademark
of
A-Tech
Corporation dba
ATA
Sensors.
|