Over
      30 years of
      excellence...

 

     Applied Technology Associates                                                1300 Britt St SE, Albuquerque, NM  87123  USA                      Tel: (505) 767-1200  Fax: (505) 768-1379                              E-mail: ContactATA@aptec.com

  Our Company
 
About ATA About Us
  Contact ATA Contact Us
 
  ATA Sensors
 
Angular Rate Sensors Angular Rate Sensors
  Calibration & Testing
Calibration & Testing
  Application Notes Application Notes
  Export Information Export Information
 
  Optical Stabilization   
 
Optical Inertial Reference Units (IRU's) Optical IRU's
  Fast Steering Mirrors Fast Steering Mirrors
 
  Government Services
 
ATA's R & D Division R & D Services
  Military Test & Evaluation Test & Evaluation
 
  Resources
 
Site Map Site Map
  Current ATA Job Postings Press Releases
 
Current ATA Job Postings Job Postings
 
New Mexico Office for Space Commercialization (NMOSC) NM Spaceport Authority
  U.S. Department of State Office of Defense Trade Controls U.S. Dept. of State
  U.S. Department of Commerce Bureau of Industry & Security U.S. Dept. of Commerce
           
                      
We want your opinion!Feedback

                            Contact Us
           to discuss your
       specific applications!

 

 

 

 







































 

 

 

 





























 

 




  Printable  .pdf   format.

For the ARS-01, the leads from the CA-01 cable should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Yellow Lead

Signal

For the ARS-01S, the leads from the CA-01 cable should be connected as follows:

Red Lead

+10 VDC

White Lead

Power Common (0 VDC)

Black Lead

Signal Common (+5 VDC Internally Generated Reference Voltage)

Yellow Lead

Signal

For the ARS-03, the leads from the CA-01 cable should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Yellow Lead

Signal

For the ARS-04E, the leads from the CA-01 cable should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Yellow Lead

Signal

For the ARS-04R, the leads should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Yellow Lead

Signal

For the ARS-06, the leads from the CA-06 cable should be connected as follows:

Red Lead

 

White Lead

 

Black Lead

 

Yellow Lead

 

For the ARS-06S, the leads from the CA-06 cable should be connected as follows:

Red Lead

 

White Lead

 

Black Lead

 

Yellow Lead

 

 For the ARS-07, the leads from the CA-01 cable should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Yellow Lead

Signal

For the ARS-09, the leads should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Yellow Lead

Signal

For the ARS-09S, the leads should be connected as follows:

Red Lead

+8 VDC

White Lead

Power Common (O VDC)

Black Lead

Signal Common (+4.1 VDC Internally Generated Reference Voltage)

Yellow Lead

Signal

For the ARS-12, the leads should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Yellow Lead

Signal

For the ARS-14, the leads should be connected as follows:

Red Lead

 

White Lead

 

Black Lead

 

Yellow Lead

 

For the ARS-15, the leads should be connected as follows:

Red Lead

 

White Lead

 

Black Lead

 

Yellow Lead

 

For the DMHD-01, the leads should be connected as follows:

Red Lead

 

White Lead

 

Black Lead

 

Yellow Lead

 

For the Dynacube™, the leads from the CA-04A cable should be connected as follows:

Red Lead

+5 VDC to +15 VDC

White Lead

-5 VDC to –15 VDC

Black Lead

Power and Signal Common (0 VDC)

Brown Lead

X-Axis Signal

Orange Lead

Y-Axis Signal

Yellow Lead

Z-Axis Signal

For the Dynacube™-S, the leads from the CA-04A cable should be connected as follows:

Red Lead

+10 VDC

White Lead

Power Common (0 VDC)

Black Lead

Signal Common (+5 VDC Internally Generated Reference Voltage)

Brown Lead

X-Axis Signal

Orange Lead

Y-Axis Signal

Yellow Lead

Z-Axis Signal


Dynacube