Specifications |
|
Dynamic |
|
|
ARS-09
Range1 .
. . . . . . . .
. . . . . . . . ±
1.75 radian/sec
(± 100
degree/sec)
ARS-09S
Range2
. . . . . . . .
. . . . . . . . ±
0.60 radian/sec
(±35
degree/sec)
Scale
Factor3
. . . . . . . .
. . . . . . . .
. . 5700
mV/radian/sec
(100
mV/degree/sec)
Bandwidth4.
. . . . . . . .
. . . . . . . .
. . . 0.3
to 1000 Hz
Cross-axis
Angular Error .
. . . . . . . .
. . <
2 %
Linear
Acceleration
Sensitivity . .
. . . . . <
0.009
radians/sec/g
(<0.5
degrees/sec/g)
Voltage
Noise PSD5
. . . . . . . .
. . . . . . 1.1
x 10-6
V2/Hz
Noise
Equivalent Angle
. . . . . . . .
. . . . <
80 microradians
( rms)
Non-linearity.
. . . . . . . .
. . . . . . . .
. . <
0.1 %
Temperature
Coefficient6.
. . . . . . . .
. . <
0.1 % Scale
Factor / ºC
|
|
Electrical |
|
|
Power
Dissipation .
. . . . . . . .
. . . . . . .<
0.3 Watts
Output
Impedence . . .
. . . . . . . .
. . . .<
100 Ohms
Grounding7
. . . . . . . .
. . . . . . . .
. . . .Mounting
flange isolated
from signal
return
|
|
Wiring |
|
|
ARS-09
|
ARS-09S
|
|
Red
Lead. . . .+Power
(+5 Vdc to +15
Vdc)
White Lead . . -Power
(-5 Vdc to -15
Vdc)
Black Lead. . . Power
and Signal
Common
(0 Vdc)
Yellow Lead. . Signal
|
Red
Lead. . . .+Power
(+10 Vdc)
White Lead . .-Power
(0 Vdc)
Black Lead. . .Signal
Common (+5
Vdc,
internally
generated
reference
voltage)
Yellow Lead . .Signal
|
|
Environmental |
|
|
Temperature
- operating . .
. . . . . . . .
. . . . -35
to +60 ºC (-31
to +140 ºF)
Temperature
- Non-operating
. .
. . . . . . . .
. -40
to +85 ºC (-40
to +185 ºF)
Humidity
. . . . . . . .
. . . . . . . .
. . . . . . . .
. Unaffected
- Epoxy sealed
unit
Linear
Acceleration8,
Max.
Operating . . .
. . . 200
g
any axis
Linear
Acceleration8,
Max. Survivable
. . . . . .200
g
any axis
|
|

Notes:
1. Based on a ±
10V output
voltage swing.
2. Based on a ±
3.5V output
voltage swing.
3. Measured @ 10
Hz.
4.
The standard
frequency
response of MHD
sensors can be
extended
significantly
by the use of
digital
filtering in
post processing
of
signal data
as covered in
ATA
Sensors'
application note
AN-01. |

5. Power spectral
density flat to
angular velocity
over
specified
bandwidth.
6. Percent
change in Scale
Factor per ºC @
100 Hz.
7. Signal return
connected to
case (isolated
from mounting
flange).
Do not ground
case to mounting
fixture to avoid
ground loops.
8.
Peak, 100 Hz
half sine. |
|