CA-01A Standard Cable
Applications: ARS-01,
ARS-01S,
ARS-03,
ARD-04E,
ARS-07,
ARS-11
Temperature
range:
-100
to
+
250
degrees
C.
Description:
This is a 7 meter (21 foot) long cable which connects directly to the sensor and has bare wire pigtail at the test equipment/power supply end for either direct attachment to the measurement and power systems, or attachment of customer supplied connectors. The cable is comprised of stranded 30 AWG silver plated copper conductors with Teflon® TFE insulation, a silver plated copper braid outer shielding and a Teflon® FEP outer jacket. The cable includes two metal screws for securely attaching the connector to the sensor.
|
|
|
|
|
|
|
|
|
|
CA-02A
Standard
Cable
Applications: ARS-01,
ARS-01S,
ARS-03,
ARS-04E,
ARS-07,
ARS-11,
ARS-12
with
ILC-01
In-line-conditioner
Temperature
range:
-100
to
+
250
degrees
C.
Description:
This is a 5.5 meter (17 foot) long cable which connects directly to the sensor and has an AirBorn M-series connector at the other end for attaching to an ILC box. The cable is comprised of stranded 30 AWG silver plated copper conductors with Teflon® TFE insulation, a silver plated copper braid outer shielding and a Teflon® FEP outer jacket. The cable includes four metal screws for securely attaching the connectors to the sensor and the ILC box. The AirBorn connector housings are custom made of machined aluminum form maximum service and durability.
|
|
|
|
|
|
|
|
|
|
CA-03A
Standard
Cable
Applications: ILC-01,
ILC-03,
DYNA-ILC
Temperature
range:
-100
to
+
250
degrees
C.
Description:
This is a 1.5 meter (5 foot) long cable which connects directly to ILC box via an AirBorn M-series connector. The cable is comprised of stranded 30 AWG silver plated copper conductors with Teflon® TFE insulation, a silver plated copper braid outer shielding and a Teflon® FEP outer jacket. The cable includes two metal screws for securely attaching the connectors to the ILC box. The AirBorn® connector housing is custom made of machined aluminum form maximum service and durability. The other end has bare wire pigtail for connecting to the test equipment/power supply. It may be either directly attached to the measurement and power systems, or attached using customer supplied connectors.
|
|
|
|
|
|
|
|
|
|
CA-03AX
Standard
Cable
Applications: ILC-03,
DYNA-ILC
Temperature
range:
-100
to
+
250
degrees
C.
Description:
This is a 1.5 meter (5 foot) long cable which connects directly to ILC-03 box via an AirBorn M-series connector for carrying the acceleration output signals from the triaxial array. The cable is comprised of stranded 30 AWG silver plated copper conductors with Teflon® TFE insulation, a silver plated copper braid outer shielding and a Teflon® FEP outer jacket. The cable includes two metal screws for securely attaching the connectors to the ILC box. The AirBorn connector housing is custom made of machined aluminum form maximum service and durability. The other end has bare wire pigtail for connecting to the test equipment/power supply. It may be either directly attached to the measurement and power systems, or attached using customer supplied connectors. This cable is not required if the ILC-03 does not have the acceleration output option.
|
|
|
|
|
|
|
|
|
|
CA-04A
Standard
Cable
Applications: Dynacube™ 2-axis, Dynacube™
3-axis, Dynacube™-S
3-axis
Temperature
range:
-100
to
+
250
degrees
C.
Description:
This is a 7 meter (22 foot) long cable which connects directly to the sensor by means of an AirBorn M-series connector. The cable is comprised of stranded 30 AWG silver plated copper conductors with Teflon® TFE insulation, a silver plated copper braid outer shielding and a Teflon® FEP outer jacket. The cable includes two metal screws for securely attaching the connector to the sensor. The AirBorn connector housings are custom made of machined aluminum form maximum service and durability. The other end has bare wire pigtail for connecting to the test equipment / power supply. It may be either directly attached to the measurement and power systems, or attached using customer supplied connectors.
|
|
|
|
|
|
|
|
|
|
CA-05A
Standard
Cable
Applications: DYNACUBE™
2
axis,
DYNACUBE™
3-axis,
with
DYNA-ILC
In-line-conditioner
Temperature
range:
-100
to
+
250
degrees
C.
Description:
This is a 5.5 meter (17 foot) long cable which connects directly to the sensor by means of an AirBorn M-series connector and has an AirBorn M-series connector at the other end for attaching to an Dyna-ILC box. The cable is comprised of stranded 30 AWG silver plated copper conductors with Teflon® TFE insulation, a silver plated copper braid outer shielding and a Teflon® FEP outer jacket. The cable includes four metal screws for securely attaching the connectors to the sensor and the ILC box. The AirBorn connector housings are custom made of machined aluminum form maximum service and durability.
|
|
|
|
|
|
|
|
|
|
CA-07A
Standard
Cable
Applications: ARS-12
Temperature
range:
-100
to
+
250
degrees
C.
Description:
This is a 1.5 meter (5 foot) long cable which connects directly ARS-12. The cable is comprised of stranded 30 AWG silver plated copper conductors with Teflon® TFE insulation, a silver plated copper braid outer shielding and a Teflon® FEP outer jacket. The cable includes two metal screws for securely attaching the connectors to the ARS-12. The test equipment end has bare wire pigtail for connecting to the test equipment/power supply. It may be either directly attached to the measurement and power systems, or attached using customer supplied connectors.
|
|
|
|
|
|
|
|
|
|
|
|
| |
|